A service gets one request a minute under a 99.9 percent SLO over 30 days. Your fast burn-rate alert pages whenever a single request fails. Is the alert broken?
Sketch your own answer first, then compare it with the one below.
A strong answer
Work out what a failure costs. A 30-day month holds 43,200 requests at this rate, so the budget is 43.2 failed requests. One failure spends about 2.3 percent of it.
Now the alert. The fast pair fires at a burn rate of 14.4 over one hour, which is an error ratio of 1.44 percent. An hour holds 60 requests, and one failure out of 60 is 1.67 percent, a burn rate of 16.7. The five-minute window holds about five requests, so one failure there is 20 percent. Both windows are over the line, and the alert fires. The rule is doing exactly what it was designed to do: page when about 2 percent of the budget has gone, which one failure has done.
So the alert is correct and the setup is wrong. A 99.9 percent target on a service this small leaves 43 failures a month, and each one matters. Ask whether the owners mean that. If the service is a background job with retries, a looser target such as 99 percent, or counting final outcomes after retries, fits better. If the target stands, add probe traffic or group the service with others so a page needs several failures.
Sources
- Betsy Beyer, Niall Richard Murphy, David K. Rensin, Kent Kawahara, Stephen Thorne (2018). The Site Reliability Workbook, chapter: Alerting on SLOs.